1KW 48V Wind Solar Hybrid Controller / Off Gird Wind Turbine Controller
Three defenses for circuit board, hierarchical design, even if small amount water enters, it will not damage the device
Standard configuration RS232 communication, it is easy to do the monitoring with the computer software. (RS485, short-range wireless is optional). Using a USB to RS232 members, more convenient to exchange data with a computer (computer with USB interface can be used).
Terminals are treated with injection molding process, wiring short circuit and cross will not occur, more safety for customers’ operating.
Battery input terminal will not be damaged with continuous reverse, and it has buzzer alarm. Avoid equipment damage and fire caused by wiring errors, and better protect the battery.
Photovoltaic panels will not be damaged with continuous reverse, and it has buzzer alarm. It will not cause wiring errors especially when work at night. (Note: reverse connection detection in the night needs manually keys intervention)
Discharge output terminal has continuous short-circuit protection, and over current protection. It is recovered after the abnormal excluded. Avoid damage of the controller or fire caused by electrical equipment fault (especially the short circuit).
Patented Wind turbines steady speed generation control method, which makes the Wind turbines not run with super speed, the Wind turbines can keep generation with a limited set speed even in the high winds, avoid direct stop of Wind turbines with over speed caused by strong wind. Greatly improve the Wind turbines generation energy and keep the safe running of the Wind turbines.
Patented Wind turbines stall current limit control methods, which makes Wind turbines not run over current, avoid the damage of expensive generator caused by heating due to over current.
This controller provides optional multiple output modes (light control, time control, light on in the morning, PWM dimming, reverse direction), which can satisfy a variety of applications.
The controller screen displays not only the current, voltage, power of conventional Wind turbines, PV, battery, and the output terminal; but also the cumulative generating capacity of Wind turbines and PV, the remaining battery power, Wind turbines speed, unloading current, and the temperature of controller.
When the terminals are up, the controller will alarm, which requires customers to use with the correct install direction, avoid the possibility of damage caused by water comes into the controller when used in the open air or due to bad weather.
Wind turbines input parameters |
|
||
Rated power of applied Wind turbines |
1000W/48V |
|
|
Rated power of the terminal |
25A dc (after rectification) |
|
|
Max. input current of the terminal |
30A dc (after rectification working <=15min) |
|
|
Max input voltage of the terminal |
120V dc |
|
|
The default current of the Wind turbines generation with limited current |
20A (settable) |
||
Wind turbines protection method |
over rev protection, over current protection, induction lightening protection |
|
|
Unloading method |
An external resistor PWM unloading |
|
|
MPPT function |
NO |
|
Wind/solar hybrid controller for 1KW off-grid system