300W 24V Wind Solar Hybrid Controller Standard Configuration Table

 
300W 24V Wind Solar Hybrid Controller Standard Configuration Table
 

  1. TYPMAR WIND SOLAR HYBRID CONTROLLER STANDARD CONFIGURATION TABLE
    TM-WSC300-A01

  2.  

    Operational Parameters

Model  No

TM-WSC300-1

Battery Rated Voltage

24V

Wind turbine Rated power

300W

Wind Turbine                       Maximum Charging Current

12A

Solar Panel                        Maximum Charging Current

15A

Solar Panel                        Maximum Open Circuit Voltage    

45V

Battery overcharge protection Voltage   

28.6V

Battery over discharge protection Voltage

21V

Battery overcharge recovery voltage

24V

Solar voltage at light control open

(2V)Adjustable

Solar voltage at light control close

(3V)Adjustable

Maximum Output Current

10A

LED  Dimmer mode           

Stepless dimming PWM intelligence
Before and after midnight                 the output power can be set up respectively

Output Control mode (factory mode)

1,normal open,                                            2,Light control : On/Off ,                                                          3,Light control: open,                                     Timing control: off .

Wind turbine unload control mode 

PWM Soft brake

Display and Setting Mode

Outlay LCD Screen and Buttons

Working Temperature

-20~+55℃/35~85%RH              (NO Dew formation)

Standby current

20±2 mA

 


    3,Standard configuration

TYPMAR WIND SOLAR HYBRID CONTROLLER STANDARD CONFIGURATION TABLE
TM-WSC300-A01

Made by :  TYPMAR  technology department

No.

Item

Parameter

Remark

1

Battery rated voltage

24 V

24v lead-acid battery or gel battery is suitable

2

Wind turbine rated power

300 W

 

3

Solar pv max voltage

45 V

It may demage the controller if the voltage over 45v

4

Solar pv max current

15A

 

5

Load max current

10A

 

6

Intelligent dimming function

yes

 

7

The battery open circuit protection function

yes

 

8

Battery over discharge alarm voltage

22V

If voltage lower than 22v , close output

9

The battery over discharge voltage recovery

24 V

After over discharge protection start, must charge the battery make sure the voltage over than 24v , then system return to normal output

10

battery voltage over charge protection

28.6 V

The battery voltage over 28.6v ,then stop charging

11

load over voltage protection

32 V

Over the voltage, shut off the output

12

The RPM of wind turbine braking

700 RPM

 

13

The typhoon judgement and protection

4 times

Turbine RPM over 700 RPM, brake for 2 minutes. Inside half an hour, four times consecutive braking judge to typhoon,controller start the typhoon protection brake

14

After the typhoon , braking time

1 hour

 

15

Wind turbine pole NO.

8 pairs

 

 

 

Products

Wind Solar Hybrid Controller